|
|
 |
Tomey OCT Optical Coherence Tomographer
|
With the CASIA SS-1000 Fourier Domain OCT, you can take high-speed and
high-resolution images for a variety of clinical situations. Due to the Swept Source Technology, three dimensional data can be captured at a speed of 0.3 to 2.4 seconds with minimal motion artifact. The SS-1000 measures 256 B-Scans over the cornea which enables the real 3D view. The high density of the B-scans offers you an entire analysis of the anterior segment.
Since the SS-1000 is a non contact system, you can take the images immediately after surgery. Corneal curvature, anterior chamber angle analysis, bleb segment analysis, measurement of corneal thickness and anterior chamber depth and the anterior segment of an opaque cornea can be analyzed with various applications. Additional to the measurement values in the single B-Scans the SS-1000 provides you with a Topographic and Pachymetry Map of the surfaces of the cornea. The individual cornea power correction, considering all physical changes in the AC is guarantor of correct calculation and relocation of the same cornea spot.
|
OCT'S AB Scan AutoLensmeter Auto Refractor Topographer/Refractor
NCT/Tonometer Corneal/Topographer Acuity/Chart/Projector Tomey Home |
|
| |
Tomey Advanced OCT SS-1000 CASIA (Not for US Market) |
|
SS-1000 CASIA (not yet available for US sale)
- With the CASIA SS-1000 Fourier Domain OCT, you can take high-speed and
high-resolution images for a variety of clinical situations. Due to the Swept
Source Technology, three dimensional data can be captured at a speed of 0.3 to
2.4 seconds with minimal motion artifact.
- The SS-1000 measures 256 B-Scans over the cornea which enables the real
3D view. The high density of the B-scans offers you an entire analysis of the
anterior segment.
- Since the SS-1000 is a non contact system, you can take the images immediately after surgery.
Corneal curvature, anterior chamber angle analysis, bleb segment analysis, measurement of
corneal thickness and anterior chamber depth and the anterior segment of an opaque cornea
can be analyzed with various applications. Additional to the measurement values in the single
B-Scans the SS-1000 provides you with a Topographic and Pachymetry Map of the surfaces of the
cornea. The individual cornea power correction, considering all physical changes in the AC is
guarantor of correct calculation and relocation of the same cornea spot.
- Specifications
- Brochure
|
|
|
| |
|
SBG/VisionEquip is currently offering special Trade-In
allowances on Canon, Topcon, Nidek, Kowa, Zeiss, Heidelberg
and other leading brand,
OCT's, Retinal Fundus Cameras, Auto Refractors and NCT Tonometers.
|
|
© 2006-2010, All
images on this website are copyrighted and protected by law.
It is unlawful to download any part of this website without expressed permission from
SBG group LLC.
|
|